Needs and Solutions

  • Some examples of use of our Maxy’s products

  • Need some help ?

  • demineralise WATER and eliminate ions responsible for scaling and corrosion

      • Capacity less than 286 litres (25°F)
        Maxy advises to you DEM’O 3 (More)
        Flow rate : 150 litres/hour
        Maximum pressure : 4 bar
        Author's imageMaxy technicianMaxy
      • Capacity less than 420 litres (25°F)
        Maxy advises to you DEM’O 4 (More)
        Flow rate : 150 litres/hour
        Maximum pressure : 4 bar
        Author's imageMaxy technicianMaxy
      • Capacity less than 570 litres (25°F)
        Maxy advises to you DEM’O 5 (More)
        Flow rate : 150 litres/hour
        Maximum pressure : 4 bar
        Author's imageMaxy technicianMaxy
    Washing of laboratory vessels - Conditioned Air - Accumulators - Radiators - Antifreeze Preparation - Photo developing

    In current use: Eliminate ions (including part of the CO2)

    Maxy advises to you : 1 SI Fixing and 1 KCR + 1 U2
    Flow rate recommended : 20 litres/hour

    Author's imageMaxy technicianMaxy

    In current use and water which is organically very loaded
    Eliminate ions (including part of the CO2) and organic substance

    Maxy advises to you

    • 1 ST Fixing
    • 1 SU Fixing with ORC Column and U2

    Flow rate recommended : 20 litres/hour

    Author's imageMaxy technicianMaxy
    ANALYSES : Medical Analyses - Physicochemical analyses - Printed circuits

    Eliminate ions (including silice and CO2)

    Maxy advises to you

    • 1 SI Fixing and 1 KCR
    • 1 SU Fixing and 1 ORC + 1 R2

    Flow rate recommended : 20 litres/hour

    Author's imageMaxy technicianMaxy
    RESEARCH : Sterile environment - Enzimology - Microbiology - ultrahigh vacuum - Mineral micro analyses - Atomic absorption - Spectrometry - Chromatography - Electron microscopy

    Eliminate Organic substances, ions, Micro-organisms (to 0,22 micron)

    Maxy advises to you :

    • 1 SI Fixing + 1 KCR + 1 ORC
    • 2 SU Fixing + 2 R2
    • 1 FLF Filter + its support (SF or DSF)

    Flow rate recommended : 20 litres/hour

    Author's imageMaxy technicianMaxy
    ULTRA-PURE WATER : Microelectronics - Electrochemistry - Cellular biology - Immunology - Macromolecular analyses

    Eliminate Organic substances, adverse ions, dissolved minerals and particles, Micro-organisms (to 0,22 micron)

    Maxy advises to you :

    • 1 MOBI.KIT and 1 DSF (support filter) or 1 SI Fixing and 1 KCR + 3 SU Fixing
    • 1 ORC Column + 2 R2
    • 1 FLF Filter and 1 M2 ion Exchanger

    Flow rate recommended : 20 litres/hour

    Author's imageMaxy technicianMaxy
    HIGH ORGANIC PURIFICATION : Microelectronics - Electrochemistry -Cellular biology - Immunology -Macromolecular analyses

    Eliminate Organic substances, adverse ions, dissolved minerals and particles,Micro-organisms (at 0,22 micron)
    Very residual low rate of Total Organic Carbon

    Maxy advises to you 1 PURO.KIT or 1 OPUR Station (60 litres/hour)
    Flow rate recommended : 30 litres/hour

    Author's imageMaxy technicianMaxy